HLP-C100 Series
HLP-C100 Series Operating Manual
-
29
-
Item
Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ra
m
ete
r
G
ro
up
08
: F
C
P
or
t S
ettin
gs
C08.01 Control Site
0: Digital and ctrl.
word; 1: Digital only;
2: Control Word
only;
0
C08.02
Control Word
Source
0: None; 1: FC RS485;
1
C08.03
Control Word
Timeout Time
0.1~6500.0
s
1.0
C08.04
Control Word
Timeout
Function
0: Off; 1: Freeze
output; 2: Stop;
3: Jogging; 4: Max.
speed; 5: Stop and
trip;
0
C08.06
Reset Control
Word Timeout
0: No Function; 1: Do
Reset;
0
C08.31 Address
FC(1~126); MODBUS
RTU(1~247);
1
C08.32 Port Baud Rate
0: 2400; 1: 4800;
2: 9600; 3: 19200;
4: 38400;
2
C08.33 FC Port Parity
0: Even Parity,1Stop
bit; 1: Odd Parity,
1stop bit; 2: No Parity,
1Stop bit; 3: No
Parity,2 Stop bits;
0
C08.35
Minimum
Response Delay
0.001~0.500
s
0.010
C08.36
Max. Response
Delay
0.010~10.000
s
5.000
C08.94 Bus Feedback 1 -32768~32767
0
C14.01
Switching
Frequency
2~6: 2kHz~6kHz;
7: 8kHz; 8: 10 kHz;
9: 12kHz; 10: 16kHz;
5
*C14.03
Over
modulation
0: Off; 1: On;
1
C14.08
Damping Gain
Factor
0~200
%
96