HLP-C100 Series
HLP-C100 Series Operating Manual
-
39
-
C01.82
Function Description
Range
Unit
Default Setting
Min Speed for Function
at Stop [Hz]
0.0~400.0
Hz 0.0
Function: Set the output f requency at which to activate par. C01.80 Function at
stop.
Description of Choice: This f unction is active in the following situations: Stop
command is given and output speed is ramped down to Min. Speed for
activating Functions at Stop; Start command is removed (standby), and
output speed is ramped down to Min. Speed for activating Functions
at Stop; DC-brake command is given, and lasts out of DC-brake delay
time.
7.3 Parameter Group 02: Brakes
C02.00 Function Description
Range
Unit
Default Setting
DC Hold Current
0~150
%
50
Function: This parameter either holds the motor (holding torque) or preheats
the motor. This parameter is active if DC Hold has been selected in
either C01.72 start f unction or C01.80 Function at Stop.
Description of Choice: Enter a value for holding current as a percentage of the
rated motor current set in par. C01.24 Motor Current. 100% DC holding
current corresponds to IM,N.
Attention: Avoid 100% current too long as it may overheat the motor.
C02.01
Function Description
Range
Unit
Default Setting
DC Brake Current
0~150
%
50
Function: This parameter is used for setting the DC brake currents that is set as
a percentage value of the rated motor current I
M, N
set in C01.24.
Description of Choice: Parameters related to the DC brake current are as
follows:
DC-brake command, see C05.1* choice (5) ;
DC brake cut in speed, see C02.04;
C02.02 Function Description
Range
Unit
Default Setting
DC Braking Time
0.0~60.0
S
10.0
Function: This parameter de
fi
nes DC brake current (C02.01) time during which
C02.0* DC -Brake