About Your System
29
E1610
Power Supply
#
(
###
W)
missing. Check
power supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supplies."
E1614
Power Supply
#
(
###
W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supplies."
E1618
Predictive
failure on
Power Supply
#
(
###
W). Check
PSU.
A power supply fan failure,
an over-temperature
condition, or a power
supply communication
error has caused the
predictive warning of an
impending power supply
failure.
See "Troubleshooting
Power Supplies."
E161C
Power Supply
#
(
###
W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its AC
input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
E1620
Power Supply
#
(
###
W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
E1624
Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the
remaining power supply
fails, the system will shut
down.
See "Troubleshooting
Power Supplies."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 29 Tuesday, September 15, 2009 10:08 AM
Summary of Contents for PowerEdge T610
Page 1: ...Dell PowerEdge T610 Systems Hardware Owner s Manual ...
Page 23: ...About Your System 23 Figure 1 5 Power Supply Status Indicator 1 power supply status 1 ...
Page 56: ...56 About Your System ...
Page 154: ...154 Installing System Components ...
Page 188: ...188 Jumpers and Connectors ...
Page 190: ...190 Getting Help ...
Page 205: ...Index 205 warranty 55 wet system troubleshooting 158 ...
Page 206: ...206 Index ...