30
About Your System
E1626
Power Supply
Mismatch. PSU1
=
###
W, PSU2
=
###
W.
The power supplies in the
system are not the same
wattage.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s
Getting
Started Guide
.
E1629
Power required
> PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
E1710
I/O channel
check error.
Review & clear
SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
E1711
PCI parity
error on Bus
##
Device
##
Function
##
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."
PCI parity
error on Slot
#
. Review &
clear SEL.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified
slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 30 Tuesday, September 15, 2009 10:08 AM
Summary of Contents for PowerEdge T610
Page 1: ...Dell PowerEdge T610 Systems Hardware Owner s Manual ...
Page 23: ...About Your System 23 Figure 1 5 Power Supply Status Indicator 1 power supply status 1 ...
Page 56: ...56 About Your System ...
Page 154: ...154 Installing System Components ...
Page 188: ...188 Jumpers and Connectors ...
Page 190: ...190 Getting Help ...
Page 205: ...Index 205 warranty 55 wet system troubleshooting 158 ...
Page 206: ...206 Index ...