About Your System
27
E122C
CPU Power
Fault. Power
cycle AC.
A power fault was
detected when powering
up the processor(s).
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E122D
Memory
Regulator
#
Failed. Reseat
DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
"Troubleshooting System
Memory."
E122E
On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1310
Fan
##
RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside of the intended
operating range.
See "Troubleshooting
System Cooling
Problems."
E1311
Fan module
##
RPM exceeding
range. Check
fan.
RPM of specified fan in
specified module is
outside of intended
operating range.
See "Troubleshooting
System Cooling
Problems."
E1313
Fan redundancy
lost. Check
fans.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of over-
heating.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan."
E1410
System Fatal
Error
detected.
A fatal system error has
been detected.
Check LCD for
additional scrolling
messages. Remove AC
power to the system for
10 seconds and restart the
system.
If the problem persists,
see "Getting Help."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 27 Tuesday, September 15, 2009 10:08 AM
Summary of Contents for PowerEdge T610
Page 1: ...Dell PowerEdge T610 Systems Hardware Owner s Manual ...
Page 23: ...About Your System 23 Figure 1 5 Power Supply Status Indicator 1 power supply status 1 ...
Page 56: ...56 About Your System ...
Page 154: ...154 Installing System Components ...
Page 188: ...188 Jumpers and Connectors ...
Page 190: ...190 Getting Help ...
Page 205: ...Index 205 warranty 55 wet system troubleshooting 158 ...
Page 206: ...206 Index ...