Setting the DPM Mode
23
Setting the DPM Mode
A program can be set to one of three Digital Program Mapping (DPM) modes, either
Drop, Pass or Map respectively. For more information, see
TS Out - DPM
(on page
LCD Setting
Description
Drop
Removes the service and its associated PMT reference
from the transport output.
Pass
Permits the source content and PMT reference to appear
in the transport output with the same references unless
the source material is mapped on another PE.
Map
Provides the flexibility to define all the outgoing PID
numbers for a PE, including those not currently on
transmission.
1
Press
MENU
to display the Main Menu.
2
Press to move to the
Setup
menu. Press
SELECT
.
3
Press five times to move to the
Outputs
menu. Press
SELECT
.
4
Press to move to the
TS Out
menu. Press
SELECT
.
5
Press twice to move to the
DPM
menu. Press
SELECT
.
6
Press
SELECT
to access the
Global
menu.
7
Press
SELECT
to choose ASI for Resync All. Press and then press
SELECT
to
continue.
8
Press
MENU
. Press to move to the
ASI
menu. Press
SELECT
. Verify the PE1
”InCh” and ”OutCh” programs.
9
Press three times to choose
Act
. Press
SELECT
. Use to select the DPM
action for the PID associated with the PE. Press
SELECT
. Press
APPLY
. Press
SELECT
to save the changes.
10
Press
MENU
six times to return to the start-up screen.
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......