Chapter 5 Web GUI Setup and Monitoring
184
1
From the user interface of the D9854/D9854-I, choose
Input
>
Disaster
Recovery
. The Disaster Recovery Setup page is displayed.
2
From the
Enable Disaster Recovery
drop-down list, choose to enable or
temporarily disable the disaster recovery feature. Choose
Yes
(default) to enable
disaster recovery. Choose
No
to set the disaster recovery into maintenance mode.
It will automatically set the Disaster Recovery back to
Yes
after five minutes.
This prevents the user from accidentally disabling disaster recovery
permanently. To disable disaster recovery, remove all the disaster recovery
configurations (Search Path settings below).
The maintenance mode allows you to perform any maintenance operations (such
as IP setup), without the unit declaring disaster and initiate a disaster recovery
search path.
Note:
Although the default is set to
Yes
, the disaster recovery is not operational
until the Search Path is configured.
3
From the
Disaster Recovery Profile
drop-down list, choose the disaster recovery
setting to use. Choose
Local
to use the disaster recovery settings configured on
the receiver, if the PNC uplink is configured to allow local disaster recovery.
Choose
Uplink
to use the PNC disaster recovery profile. The PNC disaster
recover profile is configured by the PNC uplink administrator. For more
information, contact your PNC uplink administrator.
Note:
The PNC uplink determines whether the local disaster recovery is used,
regardless of the
Disaster Recovery Profile
setting. For more information, see
Disaster Recovery
(on page 8).
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......