Chapter 5 Web GUI Setup and Monitoring
234
Duplic Mode
Description
PSI Remap
Every input PID can be mapped to only one output PID. If PID
mapping conflicts exist, DPM will use the Precedence Rule to decide
which output PID to use. All PMTs using the input PID will be
updated to reference the output PID specified by the winner.
Pkt Copy
An input PID can be mapped to multiple output PIDs. The PID will
be duplicated as many times as needed (up to a certain hardware
limitation).
Note:
This may increase the output bandwidth of the stream.
Pkt Copy
is recommended for most applications.
4
From the
Unreferenced Content
drop-down list, choose the action to use for
unreferenced content. Unreferenced content is the remainder of the transport
stream that is not filtered by the program entries. Choose
Drop
(default) to drop
all unreferenced content. Choose
Pass
to pass all unreferenced content to the
output unchanged.
5
From the
Service ID Output
drop-down list, choose whether the transcoder
should always generate PSI tables for the Mapped PE even if the selected input
channel is not available, or for only valid service channels/IDs. The following
table describes each service ID:
Svc ID
Description
Valid Ch
Only transmits the PSI tables for the mapped program if the
program exists on the input stream.
All Ch
Transmits the PSI tables for the mapped program even if the
program does not exist in the input stream.
All Ch is only valid if the PAT, NIT, SDT and PMT are set to
Regenerate.
6
If the
PSI Table Output Option
is set to Ctrl by Table, choose the regeneration
rate for those PSI tables being regenerated from the
SI Regeneration Option
drop-down list. This parameter is only used if Remapping Control is set to None.
The following table describes each PSI rate:
PSI Rate
Description
Auto
Matches the generated PSI tables' output rate to the incoming rate.
MPEG Min
Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.
SA Std
Transmits the generated PSI tables based on PowerVu standard
intervals.
7
From the
PSI Table Output Option
drop-down list, choose the action to perform
on the PSI tables for the output stream. The following table describes each
option:
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......