Chapter 6 Service and Maintenance
308
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
Signal Status
Set
RF Signal - No
Content
Cause: Loss of
ASI/RF lock. Loss
of Transport data.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.
RF Tuner
locked, but no
TS content.
Minor
1000
Signal Status
Set
Signal is lost
Cause: Loss of
ASI/RF lock. Loss
of Transport data.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.
Loss of signal.
Minor
1000
Signal Status
Set
Tuning
Parameters
Invalid
Cause: Loss of
ASI/RF lock. Loss
of Transport data.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.
One of the
tuning
parameters is
invalid.
Minor
1000
Signal Status
Clear
Signal is locked
–
Signal OK
Minor
1000
Signal Status
Clear
Tuning
Parameters Valid
–
Tuning
parameters are
valid
Minor
1000