Chapter 6 Service and Maintenance
312
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
CI Top Slot
Status
Set
No Descrambling Cause: CAM is
damaged or not
fully inserted,
hardware issue,
CAM software
crash or you don't
have subscription
rights for the card.
Remedy: Re-insert
the CAM.
All elementary
streams of all
selected
programs are
not
descrambled.
Major
10100
CI Top Slot
Status
Clear
CAM Operation
OK
–
–
Major
10100
CI Bottom Slot
Status
Set
Initialization Fail
Cause: CAM is
damaged or not
fully inserted,
hardware issue,
CAM software
crash or you don't
have subscription
rights for the
smart card.
Remedy: Re-insert
the CAM, and/or
check your rights
for the smart card.
Initialization of
CAM in bottom
slot failed.
Major
10200
CI Bottom Slot
Status
Set
No Descrambling Cause: CAM is
damaged or not
fully inserted,
hardware issue,
CAM software
crash or you don't
have subscription
rights for the
smart card.
Remedy: Re-insert
the CAM, and/or
check your rights
for the smart card.
All elementary
streams of all
selected
programs are
not
descrambled.
Major
10200
CI Bottom Slot
Status
Clear
CAM Operation
OK
–
–
Major
10200
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......