Chapter 6 Service and Maintenance
344
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
PE <n>: CA
System Error
Set
No PowerVU
support
Cause: Selected
program cannot
be descrambled.
Remedy: Check
the Installation
and Configuration
Guide for
PowerVu
descrambling
support. Ensure
that the
appropriate CAM
is inserted and
that the PE CAM
slot is assigned
correctly.
CA System
present in the
currently
selected
channel cannot
be descrambled
due to no
PowerVu ISE
or CAM
support.
Minor
93000-93031
PE <n>: CA
System Error
Set
No Matching
CAM
–
–
Minor
93000-93031
PE <n>: CA
System Error
Clear
Fault cleared
–
–
Minor
93000-93031
IP FEC Failure
(D9854-I only)
Set
FEC Encoder
Failure : FEC
bypassed
Cause: FEC FPGA
malfunction.
Remedy: Reboot
the system if FEC
is needed,
otherwise the
system will
continue to
operate bypassing
FEC.
This fault is
raised when
the FEC
Encoder or the
FEC Decoder
Lockup is
detected.
Major
95000
IP FEC Failure
(D9854-I only)
Set
FEC Decoder
Failure : FEC
bypassed
Cause: FEC FPGA
malfunction.
Remedy: Reboot
the system if FEC
is needed,
otherwise the
system will
continue to
operate bypassing
FEC.
The FEC
Encoder or the
FEC Decoder
Lockup is
detected.
Major
95000
IP FEC Failure
(D9854-I only)
Clear
Fault Cleared
–
The fault is
cleared if the
FPGA recovers
from lockup.
Major
95000
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......