Chapter 5 Web GUI Setup and Monitoring
232
12
From the
Category
drop-down list, choose the service to configure. If an input
service matches this type and Instance, then the Action will be applied. This
value is only used if the Action is set to Map. The categories are: UNKN, CDT,
LSDT, DATA, TTX, MPE, DPI, VBI, SUBT, AUD, VID, PCR or INVL.
13
Enter the
Instance
(1 to 64) of the service specified by Category to configure. If
an input service matches this type and instance, then the Action will be applied.
14
If the
Action
is set to
Map
, enter the output PID number (0 to 8192) in the
Output PID
field.
15
Click
Save
.
16
Click
OK
.
To remove a PID mapping, click the radio button of the entry you want to
remove and click
Delete
.
Synchronizing the Inputs
1
In the
DPM Program Entry Setup
table, each PE output can be synchronized to
its input according to one of the four output modes. Click the radio button of the
program entry you want to synchronize and then click
Resynchronize
or click
Resynchronize All
to synchronize the inputs to the outputs according to the
service assignments only. The Confirm Resynchronization window is displayed.
2
Click whether you want to synchronize the PE output according to the services
and then the PIDs assigned to each service, services only, PIDs only, or to
synchronize using a template.
Map Mode
Description
Resynchronize Program, PMT
PID, ES List & ES PIDs
The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
Resynchronize ES List
The receiver will synchronize the PE output according to
the available input services only, and ignore the input to
output service PID mapping.
Resynchronize ES PIDs
The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment
categories/names.
Resynchronize Template ES List
& PIDs
Allows you to preset the input to output mapping of a PE
according to the preset template. This is helpful in pre-
configuring any number of PEs for future use.
3
Click
OK
.
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......