Chapter 4 Front Panel Operation
134
10
Press
MENU
three times to exit the TS Out menu and save the data. If the
changes cannot be saved/made, a message will be displayed indicating "Bad
configuration data". The following options are available: Abandon, Exit or
Return. Select Return to re-enter the parameter.
Note:
When remapping an input program channel to an output channel, ensure
that the PIDs are mapped to different PIDs to avoid PID collisions.
Sy nchronizing Output Serv ices
Note:
The resynchronization will not synchronize the inputs if there is no valid input
on the PE or if the PE is set to channel 0.
To synchronize the output to the input Services Only:
This operation synchronizes the inputs to the outputs according to the service
assignments only. This is useful when you already have PID assignments set for the
services but want to ensure that the services are mapped correctly.
1
On the DPM menu, map the output services as desired.
2
Select
PE Resync: Svcs
. The receiver will synchronize the PE output according to
the available input services only, and ignore the input to output service PID
mapping.
To synchronize the output to the input PIDs only:
This operation synchronizes the inputs to the outputs according to the PID
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1
On the DPM menu, map the output services as desired.
2
Select
PE Resync: PIDs
. The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment categories/names.
To synchronize the output to All (Services and PIDs):
This operation synchronizes the inputs to the outputs of the current PMT according
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1
On the Detailed Program Mapping Active menu, map the outputs services as
desired.
2
Select
PE Resync: All
. The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
To synchronize the output to a Template:
Using a template allows you to preset the input to output mapping of a PE according
to the preset template. This is helpful in pre-configuring any number of PEs for
future use.
Summary of Contents for D9854
Page 21: ...Declaration of Conformity 410 Index 411 ...
Page 22: ......
Page 24: ......
Page 28: ...Chapter 1 Introduction 4 SCTE 104 pass through support on SDI output NIT Retune Recovery ...
Page 36: ......
Page 48: ......
Page 66: ......
Page 180: ......
Page 328: ......
Page 392: ......
Page 394: ......
Page 412: ......
Page 434: ...Appendix C Compliance 410 Declarationof Conformity ...
Page 439: ......