SINUS PENTA
PROGRAMMING
INSTRUCTIONS
284/452
Table 78: Parameters depending on the Drive Size and Model - Class 5T/6T / 2.
SIZE
MODEL
DEF
TFLUX
[ms]
DEF
ILIM
DEC
[%Inom
]
DEF
DCB
RAM
P
[ms]
DEF
Acc.
Time
[sec]
DEF
Dec.
Time
[sec]
S –
Ramp
s
Fire
Mode
Ramps
DEF
[sec]
Unit
Of
Meas.
Acc. /
Dec.
DEF
[sec]
Dec.
Ramp
Ext.
DEF
M1
C041
C045
C222
M2
C084
C088
C223
M3
C127
C131
C224
P009
P012
P015
P018
P010
P013
P016
P019
P021
P032
P033
P014
P020
C210
0003
300
150
50
10
10
On
10
0.1
0.2
0004
300
150
50
10
10
On
10
0.1
0.2
0006
300
150
50
10
10
On
10
0.1
0.2
0012
300
150
50
10
10
On
10
0.1
0.2
S12/S14
0018
300
150
50
10
10
On
10
0.1
0.2
0019
300
150
50
10
10
On
10
0.1
0.2
0021
300
150
50
10
10
On
10
0.1
0.2
0022
300
150
50
10
10
On
10
0.1
0.2
0024
300
150
50
10
10
On
10
0.1
0.2
S14
0032
300
150
50
10
10
On
10
0.1
0.2
0042
300
150
80
10
10
On
10
0.1
0.2
0051
300
150
80
10
10
On
10
0.1
0.2
0062
300
150
80
10
10
On
10
0.1
0.2
S22
0069
300
150
100
10
10
On
10
0.1
0.2
0076
300
150
100
10
10
On
10
0.1
0.2
0088
300
150
150
10
10
On
10
0.1
0.2
0131
300
150
150
10
10
On
10
0.1
0.2
0164
300
150
200
10
10
On
10
0.1
0.2
S32
0172
300
150
200
10
10
On
10
0.1
0.2
0181
450
100
200
100
100
Off
100
1
2
0201
450
100
220
100
100
Off
100
1
2
0218
450
100
250
100
100
Off
100
1
2
S42
0259
450
100
250
100
100
Off
100
1
2
0290
450
100
250
100
100
Off
100
1
2
0314
450
100
250
100
100
Off
100
1
2
0368
450
100
250
100
100
Off
100
1
2
S52
0401
450
100
250
100
100
Off
100
1
2
0457
450
100
250
100
100
Off
100
1
2
0524
450
100
250
100
100
Off
100
1
2
0598
450
100
250
100
100
Off
100
1
2
S65
0748
450
100
250
100
100
Off
100
1
2
S70
0831
450
100
250
100
100
Off
100
1
2
0964
450
100
250
100
100
Off
100
1
2
S75
1130
450
100
250
100
100
Off
100
1
2
S80
1296
450
100
250
100
100
Off
100
1
2
1800
450
100
250
100
100
Off
100
1
2
S90
2076
450
100
250
100
100
Off
100
1
2
2xS42
0459
450
100
250
100
100
Off
100
1
2
0526
450
100
250
100
100
Off
100
1
2
0600
450
100
250
100
100
Off
100
1
2
0750
450
100
250
100
100
Off
100
1
2
2xS52
0828
450
100
250
100
100
Off
100
1
2
0960
450
100
250
100
100
Off
100
1
2
3xS52
1128
450
100
250
100
100
Off
100
1
2