PROGRAMMING
INSTRUCTIONS
SINUS PENTA
113/452
P067 Keypad and Terminal Board UP/DOWN Ramp
P067
Range
0
6501
0 sec
6500s Quadratic
Default
6501
Quadratic
Level
ADVANCED
Address
667
Function
Reference may be increased or decreased with input digital signals
UP
and
DOWN
,
or using the
▲
and
▼
keys from the keypad (local mode).
Reference increment or decrement is obtained by adding to the current reference a
quantity which will be increased or decreased with a time ramp.
Parameter
P067
indicates the ramp time to increase the reference from zero to the
preset speed (or torque) maximum absolute value, i.e. the max. value between
absolute values Spd_Min and Spd_Max (or Trq_Min and Trq_Max).
If
motor
1
is
active,
Spd_Min=
C028
,
Spd_Max=
C029
,
Trq_Min=
C047
,
Trq_Max=
C048
.
P068 Storage of UP/DOWN Values at Power Off
P068
Range
0
1
0: Disabled, 1: Enabled
Default
1
1: Enabled
Level
ADVANCED
Address
668
Function
If
P068
=1, the Speed/Torque or PID references added through input digital signals
UP
and
DOWN
or with the
INC
and
DEC
keys (local mode), are stored at the drive
power off and are added to the start reference when the drive is restarted.
This function allows storing he reference value obtained with
UP
and
DOWN
signals.
P068a Reset UP/DOWN Speed/Torque at Stop
P068a
Range
0
1
0: NO, 1: YES
Default
0
0: NO
Level
ADVANCED
Address
940
Function
If
P068a
=1: [Yes], the Speed/Torque reference sent via the
UP
/
DOWN
digital signals
or with the
▲
and
▼
keys in the keypad is reset whenever the START command for
the drive is disabled and the deceleration ramp is finished.
P068b Reset UP/DOWN PID at Stop
P068b
Range
0
1
0: NO, 1: YES
Default
0
0: NO
Level
ADVANCED
Address
941
Function
If
P068b
=1: [Yes], the PID reference sent via the
UP
/
DOWN
digital signals
or via the
▲
and
▼
keys in the keypad) is reset whenever the START command for the drive is
disabled and the deceleration ramp is finished.