SINUS PENTA
PROGRAMMING
INSTRUCTIONS
352/452
C230 Voltage Level of DC Bus in Power Down
C230
Range
250
450 for Class 2T
400
800 for Class 4T
500
960 for Class 5T
600
1150 for Class 6T
250
450 V for Class 2T
400
800 V for Class 4T
500
960 V for Class 5T
600
1150 V for Class 6T
Default
339 for Class 2T
679 for Class 4T (380
480V)
707 for Class 4T (481
500V)
813 for Class 5T
976 for Class 6T
339 V for Class 2T
679 V for Class 4T (380
480V)
707 V for Class 4T (481
500V)
813 V for Class 5T
976 V for Class 6T
Level
ENGINEERING
Address
1230
Function
Determines the reference value for DC bus voltage in case of automatic
deceleration in Power Down;
C225
= Yes V.
C231 PI Proportional Constant for Automatic Deceleration
C231
Range
0
32000
0.000
32.000
Default
50
0.050
Level
ENGINEERING
Address
1231
Function
Proportional coefficient used in PI regulator controlling automatic deceleration
in case of Power Down;
C225
=Yes V.
C232 PI Integral Time for Automatic Deceleration
C232
Range
1
32000
0.001
31.999 sec
32000 = Disabled
Default
500
0.5 sec
Level
ENGINEERING
Address
1232
Function
Integral time used in PI regulator controlling automatic deceleration in case of
Power Down;
C225
=Yes V.