SINUS PENTA
PROGRAMMING
INSTRUCTIONS
332/452
3 6.2.
List of Parameters C189 to C199
Table 97: List of parameters C189 to C199.
Paramete
r
FUNCTION
User Level
MODBUS
Address
DEFAULT VALUES
C189
Encoder/Frequency input operating
mode
BASIC
1189
0 [Not used,
Not used]
C190
Number of pls/rev for encoder A
BASIC
1190
1024
C191
Number of pls/rev for encoder B
BASIC
1191
1024
C192
Speed searching error timeout
ENGINEERING
1192
5.00 sec
C193
Error between reference and speed
ENGINEERING
1193
300 rpm
C194
Tracking error alarm enable
ENGINEERING
1194
1: Active
C195
Filter time constant over value of
feedback from encoder
ENGINEERING
1195
5.0 ms
C196
Filter time constant over value of
reference from encoder
ENGINEERING
1196
5.0 ms
C197
Number of channels of Encoder A
ENGINEERING
1197
0:2 Squaring channels
C198
Number of channels of Encoder B
ENGINEERING
1198
0:2 Squaring channels
C199
Encoder sign reversal
ENGINEERING
1199
0[Fdbk.NO;Ref.NO]
C189 Encoder/Frequency Input Operating Mode
C189
Range
0
14
See Table 98
Default
0
0 [Not used; Not used]
Level
BASIC
Address
1189
Function
This parameter determines the operating mode of quick acquisition digital inputs.
If MDI8 is used as a frequency input, the option board for encoder B is not
required. MDI6 digital input may be used as a frequency input; if used along with
MDI7, it can be used for encoder A reading.
Reading both encoders A and B can be programmed; parameter
C189
defines
the encoder to be used as a reference source (if set as a speed/torque reference
source in the MOTOR CONTROL MENU or as a PID reference source in the PID
CONFIGURATION MENU) and the encoder to be used as a speed feedback.
Configuration allowed for quick acquisition digital inputs is shown in Table 98.
If the encoder is used as a reference source, the detected speed value will
be saturated and scaled based on values set in P073 and P074 respectively
(minimum and maximum value for the encoder).
Example
:
C189
[A Reference; B Unused],
P073
[–1500rpm],
P074
[1500rpm] if the encoder
is used as a PID reference, the reference measure is expressed as a percentage
of the max. value [|
P073
|; |
P074
|].
If a frequency input is selected, its readout is saturated and scaled based
on parameters P071 and P072 respectively (minimum and maximum value
for the frequency input).