471
Query Command Library
Parameters
Examples
$PASHQ,DIP
$PASHR,DIP,RIP,192.65.54.1,PRT,80,IPP,P*xx
$PASHQ,DIP
$PASHR,DIP,RIP,www.ashtech.com,PRT,8080,IPP,Q*xx
Relevant Set
Command
$PASHS,DIP
See also
$PASHQ,MDM
DPO: Delta Position
Function
This command is used to output a DPO message containing
the components of the last computed vector (baseline) as
well as other information about the position solution.
Command Format
Syntax
$PASHQ,DPO[*cc]
Response Format
Syntax
$PASHR,DPO,d1,d2,m3,f4,c5,f6,c7,f8,c9,f10,f11,f12,f13,f14,f15,f16,s17*cc
Parameter
Description
Range
RIP,s1
IP address
(xxx.xxx.xxx.xxx) or host
name
IP address:
000.000.000.000 to 255.255.255.255
or host name
PRT,d2
Port number
0-65535
LGN,s3
User name (optional)
20 char. max.
PWD,s4
Password (optional)
20 chars max.
IPP,c6
Internet port used on the
receiver to establish the
connection with the base
(server):
• E: Internal modem
(default)
• P: Ethernet stream 1
• Q: Ethernet stream 2
E, P, Q
*cc
Checksum
*00-*FF
Summary of Contents for HDS800
Page 1: ...Reference Manual HDS800...
Page 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Page 54: ...38 Receiver Description...
Page 104: ...88 Using the Web Server...
Page 189: ...173 Web Server Help Files Collection Configuration Tab...
Page 266: ...250 Using Serial Commands...
Page 606: ...590 Query Command Library...
Page 619: ...603 Data Output...
Page 628: ...612 Data Output...
Page 650: ...634 Troubleshooting...
Page 660: ...644 Other Procedures Memos...
Page 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Page 677: ......