414
Set Command Library
Command Format
Syntax
$PASHS,STI,d[*cc]
Parameters
Examples
Defining station ID “150” for use in RTCM messages:
$PASHS,STI,150*23
Note
If the chosen station ID is beyond the upper limit in the
applicable range, then the value “31” is chosen instead (i.e.
“31” instead of “56” for example if CMR/CMR+ messages
are broadcast, or “31” instead of “1041” for example if
RTCM 2.3 messages are broadcast).
Relevant Query
Command
$PASHQ,STI
See also
$PASHS,BAS
$PASHS,MOD,BAS
SVM: Setting the Maximum Number of Observations in the PVT
Function:
This function is used to set the maximum number of code and
doppler observations used in the PVT calculation.
Command Format
Syntax
$PASHS,SVM,d1[*cc]
Parameter
Description
Range
d
Station ID
0-1023 (RTCM 2.3)
0-4095 (RTCM 3.x and ATOM)
0-31 (CMR & CMR+)
*cc
Optional checksum
*00-*FF