455
Query Command Library
Command Format
Syntax
$PASHQ,CP2,AFP[*cc]
Response Format
Syntax
$PASHR,CP2,AFP,f*cc
Parameters
Example
$PASHQ,CP2,AFP
$PASHR,CP2,AFP,99.0*1C
See also
$PASHS,CP2,AFP
CPD,AFP: Ambiguity Fixing Parameter
Function
This command is used to read the current setting for the
ambiguity fixing parameter.
Command Format
Syntax
$PASHQ,CPD,AFP[*cc]
Response Format
Syntax
$PASHR,CPD,AFP,f*cc
Parameters
Example
$PASHQ,CPD,AFP
$PASHR,CPD,AFP,99.0*6A
See also
$PASHS,CPD,AFP
Parameter
Description
Range
f
Ambiguity fixing value. “0” means the
receiver will stay in Float mode.
0, 95.0, 99.0, 99.9
*cc
Checksum
*00-*FF
Parameter
Description
Range
f
Ambiguity fixing value. “0” means the
receiver will stay in Float mode.
0, 95.0, 99.0, 99.9
*cc
Checksum
*00-*FF