530
Query Command Library
Parameters
Comments
With no internal battery in, fields f4, d5 and d7 are all empty.
With no external power source applied, field f6 is empty.
The lower and upper limits of power voltage (f9, f10) control
the mechanism through which the receiver will be powered on
or off automatically if the DC voltage applied to the power
input is respectively within or out of these limits (making this
mechanism operational requires that the slide switch located
at the bottom of the compartment be pushed to the right).
Example
$PASHQ,PWR
$PASHR,PWR,6.8,9.1,2,,,11.6,,44*0D
Relevant Set
Command
$PASHS,PWR,PAR
Parameter
Description
Range
f1
Battery voltage threshold, in volts, triggering a low-bat-
tery alarm
6.7-8.4
f2
External power voltage threshold, in volts, triggering a
low-power alarm
9.0-28
d3
Power source:
• 0: Internal battery
• 1: External battery
• 2: External DC source
0-2
f4
Battery DC output voltage, in volts
0.0-12.0
d5
Percentage of remaining battery energy
0-100
f6
DC input voltage from external power, in volts
0.0-30.0
d7
Battery charging status:
• 0: Charging
• 1: Discharging
• 2: Fully charged
0-2
d8
Internal temperature, in °Celsius
f9
Lower limit of DC voltage, in volts, controlling auto-
matic power on/off
9.0-36.0
f10
Upper limit of DC voltage, in volts, controlling auto-
matic power on/off
9.0-36.0
*cc
Checksum
*00-*FF
Summary of Contents for HDS800
Page 1: ...Reference Manual HDS800...
Page 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Page 54: ...38 Receiver Description...
Page 104: ...88 Using the Web Server...
Page 189: ...173 Web Server Help Files Collection Configuration Tab...
Page 266: ...250 Using Serial Commands...
Page 606: ...590 Query Command Library...
Page 619: ...603 Data Output...
Page 628: ...612 Data Output...
Page 650: ...634 Troubleshooting...
Page 660: ...644 Other Procedures Memos...
Page 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Page 677: ......