616
Troubleshooting
If neither of these two actions resolves your problem, you
may have a malfunctioning receiver. Contact your local
dealer or email Ashtech Technical Support for assistance.
2.
If the memory is not full
(>0%), you may have a
malfunctioning receiver. Contact your local dealer or email
Ashtech Technical Support for assistance.
Radio Data Link Fails to Provide Base Corrections to Rover
The Data Link icon is displayed on the rover’s General Status
screen when base corrections are received and a float or fixed
solution is available. Next to it is the age of corrections, a
value which should not normally exceed a few seconds when
the data link operates smoothly.
After examining the General Status screen, you determine
that the rover is not receiving data. Follow the outline below
to troubleshoot this problem.
Step 1. Is the
Receiver Fitted
with the
Appropriate Radio
Module?
The radio module used should be compatible with the radio
transmitter used at the base. Several sub-bands and channel
bandwidths are available for the radio
.
1.
If you are using the right module
, go to step 2.
2.
If you are not using the right module
, turn off the receiver
and replace the module with the right one. You then need
to restore the default settings in the receiver (by pressing
the
Reset Factory Defaults
button in FAST Survey’s
Equip>GPS Utilities
or pressing the Log+ Power
buttons simultaneously on the front panel) so the receiver
can recognize and use the new module. If using the right
module does resolve the problem, go to step 2.
NOTE: There is no particular action required to power up
the radio module other than to power up the receiver. This
automatically applies power to the radio module.
RTK Base
RTK Rover
PP Base
PP Rover
Relevant to
•
Summary of Contents for HDS800
Page 1: ...Reference Manual HDS800...
Page 16: ...x Enabling a Firmware Option 639 Decoding an NTRIP Source Table 639 Logging Raw Data 642...
Page 54: ...38 Receiver Description...
Page 104: ...88 Using the Web Server...
Page 189: ...173 Web Server Help Files Collection Configuration Tab...
Page 266: ...250 Using Serial Commands...
Page 606: ...590 Query Command Library...
Page 619: ...603 Data Output...
Page 628: ...612 Data Output...
Page 650: ...634 Troubleshooting...
Page 660: ...644 Other Procedures Memos...
Page 676: ...X XDR 110 112 587 Z Z Blade 1 ZDA 347 431 588...
Page 677: ......