Chapter 7 Performance Test
7-12
7.2 Performance Test for Error Detector
This section describes the performance test items for the error detector.
Maximum input level and patterns
Before testing the performance of the ED, confirm that the performance of
the tested pulse pattern generator satisfies the specifications.
7.2.1
Required equipment
The following table shows the equipment required for the performance
test.
Before starting performance tests, warm up the MP2110A and the
measuring instruments for at least 1 hour.
Table 7.2.1-1 Equipment for Performance Test
Product Name
Required Performance
Recommended
Equipment
Sampling
oscilloscope
Electrical interface
Bandwidth: 40 GHz or more
MP2110A
(Anritsu)
Fixed
attenuator
20 dB, K connector
Bandwidth: DC to 40 GHz
41KC-20
(Anritsu)