5.2 PPG/ED
Panel
5-11
5
How to Op
erate BERT
PRBS
Pattern
Generation
Polynomial
Pattern
Length
Maximum
number of
contiguous 1s
Maximum
number of
contiguous 0
2^7–1 1+X
6
+X
7
127
7 6
2^9–1 1+X
5
+X
9
511
9 8
2^15–1 1+X
14
+X
15
32767
15 14
2^23–1 1+X
18
+X
23
8388607
23 22
2^31–1 1+X
28
+X
31
214748647
31 30
The ratio of 1s to the PRBS pattern length is 50%.
1/2 Clock Pattern
“1/2 Clock Pattern” means the repeating pattern of “1” and “0”.
The pattern of which the clock frequency is divided in half is output from
the
Data Out
connector and
Data
Out
connector.
Figure 5.2.3-2 Relationship between Data and Clock when 1/2 Clock
Pattern is set
1/16 Clock Pattern
“1/16 Clock Pattern” means the repeating pattern of “11111111” and
“00000000”.
The pattern of which the clock frequency is divided in one-sixteen is
output from the
Data Out
connector and
Data
Out
connector.
Figure 5.2.3-3 Relationship between Data and Clock when 1/16 Clock
Pattern is set
Clock
Data
1
1
0
1
0
1
0
1
0
0
Pattern
data
Time
Clock
Data
1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0
Pattern
data
Time
Summary of Contents for BERTWave Series
Page 26: ...VI...
Page 74: ...Chapter 1 Outline 1 48...
Page 166: ...Chapter 4 Screen Operation 4 24...
Page 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Page 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Page 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Page 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Page 432: ...Appendix A Specifications A 36...
Page 458: ...Appendix D Performance Test Record Form D 12...
Page 466: ...Index Index 6...