7.1 Performance Test for Pulse Pattern Generator
7-7
7
Performance T
est
(3) Procedure
1. Connect the coaxial terminator to the
PPG1
Data
Out
connector.
2. Connect
the
Clk Out
connector and the
Trigger Clk In
connector
of the sampling oscilloscope using a coaxial cable.
3. Connect
the
PPG1 Data Out
connector and the
Ch A In
connector
of the sampling oscilloscope using a coaxial cable.
4. Click
PPG/ED Ch1. Configure the settings as shown below:
Item
Setting Value
Reference Clock
Internal
Bit Rate
100GbE/4 (25.78125G), 0 ppm
Clock Output
Ch1/2
PPG Amplitude
0.1
External ATT
0
Test Pattern (PPG)
PRBS 2^31–1, POS
PPG Data/XData
ON
5. Click
Scope. Configure the settings as shown below:
Dialog Box
Item
Setting Value
Setup Signal Type
NRZ
Sampling
Mode
Eye
Number
of
Samples
4050
Accumulation
Time
Persistency
Time
10.0
sec
Amplitude Scale
100
mV/Div
Offset
0
mV
Time
Tracking
Symbol Rate: PPG,
Divide Ratio: Clock
Output*
Measure -
Display
On
Amplitude/Time Item
(A) Eye Amplitude
Rise/Fall
Time 20/80%
*: Set it to Off when using two MP2110As (Figure 7.1.3-3 and
Figure 7.1.3-4), and input Divide Ratio.
6. Click
Ch A, Sampling Hold, and Auto Scale of Scope, and
measure the eye amplitude.
7. Click
PPG/ED Ch1.
8. Set Amplitude to 0.8 Vp-p.
9. Click
Scope. Measure the EYE amplitude on the sampling
oscilloscope.
Summary of Contents for BERTWave Series
Page 26: ...VI...
Page 74: ...Chapter 1 Outline 1 48...
Page 166: ...Chapter 4 Screen Operation 4 24...
Page 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Page 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Page 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Page 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Page 432: ...Appendix A Specifications A 36...
Page 458: ...Appendix D Performance Test Record Form D 12...
Page 466: ...Index Index 6...