Chapter 6 How to Operate Sampling Scope
6-42
Table 6.2.4-7 Items of Jitter Measure Dialog Box - Advanced Tab
Item
Description
TJ Measurement
BER
Sets the bit error rate to measure the eye opening in the Bathtub graph.
Fixed RJ
Set Off to display the graph using RJ calculated from the measured
waveform.
Set On to display TJ graph by setting RJ an arbitrary value.
It is used to simulate the change of TJ by changing RJ value.
RJ Value
TJ is calculated with the use of the value entered here when Fixed RJ is
set to On.
Correction Factor
When setting the display to On, DJ (Scale), the correction coefficients of
RJ (Scale) and RJ (rms) can be entered. Corrected value(s) is(are)
indicated by “*1” in the measurement result display area.
DJ (Scale)
It is the correction coefficient of DJ.
The value calculated from the waveform multiplied by this number is
displayed in the measurement result.
Set to 1.00 for no correction.
RJ (Scale)
It is the correction coefficient of RJ.
The value calculated from the waveform multiplied by this number is
displayed in the measurement result.
Set to 1.00 for no correction.
RJ (rms)
RJ (d-d), RJ (rms) correction coefficient.
RJ is corrected with the following formula.
2
2
r
m
RJ
σ
m
:
Standard deviation of measured RJ
σ
r
: Correction Coefficient
RJ: RJ (d-d), RJ (rms) after correction.
When not correcting, set Correction Factor to Off.
Define Threshold
Sets the position detection method of the cross point relative to the
amplitude of the eye pattern.
Set it to Auto for automatic detection and Manual to specify the
position.
Manual Crossing
When Define Threshold is Manual, set the cross point position within
the range of 30 to 70% of the amplitude.
Summary of Contents for BERTWave Series
Page 26: ...VI...
Page 74: ...Chapter 1 Outline 1 48...
Page 166: ...Chapter 4 Screen Operation 4 24...
Page 210: ...Chapter 6 How to Operate Sampling Scope 6 16 Figure 6 2 2 4 Switching Graph Display...
Page 309: ...6 9 Measuring Waveform 6 115 6 How to Operate Sampling Scope Figure 6 9 5 1 Marker Display...
Page 322: ...Chapter 6 How to Operate Sampling Scope 6 128...
Page 380: ...Chapter 8 Maintenance 8 14 7 Click Reinstall Windows 8 Click Yes...
Page 432: ...Appendix A Specifications A 36...
Page 458: ...Appendix D Performance Test Record Form D 12...
Page 466: ...Index Index 6...