1. Setting Welding Schedules
93
ML-2350A/2351A
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
When this screen appears, output pin No.9 (upper limit of lamp input) of the external
output signal EXT.I/O (1) connector is open-circuited for output.
Press the "TROUBLE RESET" button to clear the screen display.
⇒
After the screen display is reset, pin No.9 of the EXT.I/O (1) connector output
remains in an open circuit output state. If the power supply is less than the upper
limit value of lamp input power when the flashlamp lights next time, the open
circuit output state is returned to a closed circuit state. The open circuit output
state is also reset by turning on the power supply again.