56
ML-2350A/2351A
6. Connecting the External Communication Conversion Adapter (Option)
6. Connecting the External Communication Conversion
Adapter (Option)
To perform laser welding by external communication control (RS-485 CONTROL)
by using a control unit mounting RS-232C such as personal computer, the optional
conversion adapter for external communication "RS-232C/RS-485 conversion
adopter" is required.
⇒
For making a connection to a PLC provided with RS-485, the conversion adapter
for external communication is not required.
Item required
RS-232C/RS-485 conversion adapter, RS-485 cable, and RS-232C cable
Operating Procedure
(1) Connect the RS-485 cable to the RS-485 (1) or RS-485 (2) connector of the main
unit.
(2) Connect the RS-232C cable to the RS-232C connector of the personal computer
or the like through the "RS-232C/RS-485 conversion adapter."
RS-485 Cable
Personal computer, etc.
RS-485 (1) Connector
RS-485 (2) Connector
RS-232C/RS-485
conversion adapter
RS-232C Cable
Summary of Contents for ML-2350A-CE