1. Setting Welding Schedules
77
ML-2350A/2351A
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
SWITCH 5
1 to 5
6
7
•
8
Switches the functions assigned to 1 to 8 of "SWITCH 5" to ON/OFF.
1, 2, 3, 4, and 5: (Enabled only when the branch shutter is put under independent
control)
Press the setting buttons of "1" to "5" of "SWITCH 5" to set the timesharing unit
numbers to be operated to ON. "1" to "5" of "SWITCH 5" are associated with
the timesharing units 1 to 5. Accordingly, set them to ON within the number of
mounted timesharing units.
6: At ON, the function automatically switching the screen from the SCHEDULE
screen to the MONITOR screen becomes invalid.
7 and 8: Unused.
SWITCH 6
1
2
3
4 to 8
Switches the functions assigned to 1 to 8 of "SWITCH 6" to ON/OFF.
1: At ON, the contents of the other SCHEDULE No. can be referred even in the
control mode other than PANEL CONTROL.
2: At ON, the limit of Error No.53 POWER FEEDBACK TROUBLE becomes 0.5%.
At OFF (default), the limit is 1.0%.
3: At ON, when using the fade-in/out function, an upper/lower limit judgment of the
laser energy monitor is performed even for shots other than the shot output at
100.0%.
4, 5, 6, 7, and 8: Unused.
BACK
Returns to the INITIALIZE screen.
⇒
When the setting of SWITCH 1 or SWITCH 6 has been changed, be sure to turn
OFF the power to make the setting effective before use.
Summary of Contents for ML-2350A-CE
Page 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 118: ......
Page 128: ......
Page 150: ......
Page 174: ......
Page 179: ...Maintenance Part...
Page 180: ......
Page 209: ...Appendixes...
Page 210: ......