172
ML-2350A/2351A
4. Commands
Resetting the Appropriate Number of Outputs
The command (code: C2) to reset the appropriate number of outputs (GOOD
COUNT) is explained below.
CH1/CH0
Equipment No. (CH1 = tens digit, CH0 = units digit)
ACK or NAK
The Laser accepts the command only when in external communication
control (RS-485 CONTROL) mode. It returns a [NAK] when in any other
control method.
Reading Error No. at Occurrence of Trouble
The command (code: RT) to read error No. at occurrence of trouble is explained below.
CH1/CH0
Equipment No. (CH1 = tens digit, CH0 = units digit)
E1/E0
Error No. (E1 = tens digit, E0 = units digit)
All error numbers are transmitted. If no error has occurred, the error No. is to
be [00].
For the contents corresponding to error No., refer to "Table of Error
Contents" on page 173.