MONITOR Screen
On the MONITOR screen, the measured value of monitored laser light is checked
and the monitor value range and the upper limit value of flashlamp input power are
set.
How to see the displayed items
: Settable item
ENERGY
Displays the measured value (J) of laser energy. Each time laser light is
output, the laser energy is measured and its value is displayed. In the
case of a high-speed repeated output, however, the energy is displayed at
certain intervals because the display timing is too quick.
AVERAGE
Displays the average power (W) of output laser light per second. An
upper/lower limit judgment is not performed.
HIGH
LOW
Sets the upper limit value "HIGH" and lower limit value "LOW" of the laser
energy to be monitored.
When the laser energy comes out of the set value range, a monitor trouble
is output. Press the TROUBLE RESET button to clear the trouble.
SHOT COUNT
Displays the total number of laser light outputs.
Refer to this number when replacing the flashlamp.
To reset the display to 0, perform a reset operation on the STATUS screen.
GOOD COUNT
Displays the appropriate number of laser light outputs. The appropriate
number of outputs means the laser light output within the allowable energy
range set at "HIGH" and "LOW."
To reset the display to 0, perform a reset operation on the STATUS screen.
LAMP INPUT
POWER
Displays the flashlamp power. The power input to the lamp is displayed by
the ratio (%) to the maximum input value native to the lamp.
<Note>
When the laser is used in the status where a value of 80% or more is
displayed, the replacement cycle of the flashlamp may be shortened.
REFERENCE
SETTING
Sets the upper limit value of lamp input power in the range of 0 to 100%.
Usually, this value is set to 100%. The set value becomes the reference
value for flashlamp deterioration notice. When the set value is exceeded, a
screen to notify the approach of the flashlamp replacement time is displayed.
⇒
For the common items in the upper/lower part of the screen, refer to page 63.
Summary of Contents for ML-2350A-CE
Page 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 118: ......
Page 128: ......
Page 150: ......
Page 174: ......
Page 179: ...Maintenance Part...
Page 180: ......
Page 209: ...Appendixes...
Page 210: ......