208
ML-2350A/2351A
2. Troubles not Displaying Fault Code
Operation for Closing Interlock
2. Troubles not Displaying Fault Code
States of Laser
Measures
Laser output increases though monitor displays normal value.
(When welding spot is not clean or spatter increases.)
Adjust PEAK POWER and output time. If the
laser does not improve though the setting
is adjusted, optical axis of resonator may
have been dislocated. For adjusting the axis,
consult us.
Laser output decreases though monitor displays normal
value. (When welding is not performed or weld strength is not
enough.)
REMOTE INTERLOCK
connector
Error output
Resonator shutter
Branch shutter state
Timesharing unit
TROUBLE RESET input
OFF during error
At PANEL CONTROL or RS-485 CONTROL,
they remain OFF even if the TROUBLE
RESET signal is input. They don't return
to the previous state.
Open
Close
Error
Normal
ON
OFF
ON
OFF
}