1. Name and Function of Each Section on the Front Side
31
ML-2350A/2351A
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
(8) REMOTE
INTERLOCK
Connector
Connect it to the Remote Interlock for emergency stop.
When this connector is closed, the resonator shutter and branch shutter
of the laser welder are closed to shut off the laser light output.
(9) Cooling Water
Tank
Holds secondary cooling water used for cooling the YAG rod, flashlamp
and its power supply.
(10) Water Level
Label
Shows proper level of the secondary cooling water.
(11) Ion-Exchanger
Increases purity of the secondary cooling water.
(12) Water Filter
Removes fur and other contaminants from secondary cooling water.
(13) Drains
For draining water in the piping to prevent freeze.