Setting the Output Status Check Screen (MONITOR Screen)
In the following, the method of setting the MONITOR screen is explained. On
this screen, the measured energy value of output laser light is checked, the
energy range to be monitored is set, and the upper limit value of flashlamp
input power is set.
Checking the Measured Energy Value of Laser Light
When laser light is output, the MONITOR screen is automatically displayed and a
measured energy value is displayed. The measured energy value of the last output
laser light can also be checked by the corresponding SCHEDULE number if a
registered SCHEDULE number is entered.
(1) Press the "SCHEDULE" setting button.
Enter the SCHEDULE number.
The measured energy value of the last output laser light and laser light waveform
are displayed according to the set SCHEDULE.
Setting the Laser Energy Range To Be Monitored
Set the upper limit value and lower limit value of energy to be monitored. This set
range is used as the allowable energy range.
(1) Press the "HIGH" setting button.
Enter the upper limit value.
The upper limit value of allowable energy is registered.
(2) Press the "LOW" setting button.
Enter the lower limit value.
The lower limit value of allowable energy is registered.
Summary of Contents for ML-2350A-CE
Page 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 118: ......
Page 128: ......
Page 150: ......
Page 174: ......
Page 179: ...Maintenance Part...
Page 180: ......
Page 209: ...Appendixes...
Page 210: ......