186
ML-2350A/2351A
2. Maintenance of the Cooler Unit Section
Draining Water from the Primary Cooling Water
When the laser welder must be moved or transferred or its operation is stopped over
one month, drain the primary cooling water.
⇒
For changing the ion-exchange resin for repacking, changing the ion-exchanger,
changing the water filter, and changing the secondary cooling water, the primary
cooling water does not need to be drained.
⇒
For the primary cooling water, use tap water or clean industrial water.
Item required
Water feed pump and bucket (container to receive water)
Operating Procedure
(1) Remove the 2 hoses connected from the outside and drain water.
⇒
Sometimes, water may spout out hard. Take care not to splash water on the
laser welder. If the laser welder is splashed with water, wipe it off completely with
a cloth.
(2) Connect both of the cooling water inlet and outlet with a hose as shown.
Hose band