88
ML-2350A/2351A
1. Setting Welding Schedules
Resetting the Number of Laser Light Outputs
Reset the numeric values of "SHOT COUNT" (total number of laser light outputs) or
"GOOD COUNT" (appropriate number of laser light outputs) that are displayed on the
MONITOR screen.
(1) Press the "RESET" button of "SHOT COUNT" or "GOOD COUNT" of RESET
COUNT.
The numeric value is reset and "000000000" is displayed.
Setting the Count-notification Function
When "SHOT COUNT" (total number of laser light outputs) or "GOOD COUNT"
(appropriate number of laser light outputs) that are displayed on the MONITOR
screen reaches the set number, a message is displayed. This function will be of
assistance for maintenance or manufacturing control.
(1) Press the "SHOT COUNT" or "GOOD COUNT" setting button of PRESET COUNT.
Enter an optional output count.