3. Operating Procedure
123
ML-2350A/2351A
Chapter 3 Laser W
elding by Laser Controller (P
ANEL
CONTROL)
Introduction Part
Installation
and
Preparation
Part
Operating Part
Maintenance Part
Appendixes
After completion of charging, the READY !! screen appears for 0.5 sec.
After the READY !! screen appears, the screen (SCHEDULE screen, STATUS
screen, or MONITOR screen) displayed at the previous completion appears.
2
Setting Output Schedules
As an example, the procedure for setting SCHEDULE No.05, laser output peak value
5.00 kW, FLASH1 laser output time 3.6 ms/output value 60%, and up-slope 0.6 ms is
explained below.
⇒
For how to set the output conditions for seam welding, refer to "Setting the output
conditions for seam welding" on page 83.
(1) Press the "SCHED" button to display the SCHEDULE screen.
(2) Press the "SCHEDULE" setting button.
Enter the SCHEDULE number by using the numeric keypad and then press the
ENT key.
In this example, set #05.
⇒
As the SCHEDULE number, it is possible to set 32 schedules of #00 to #31. In
"FORM", the fixed waveform "FIX" or flexible waveform "FLEX" can be specified.
⇒
When the registered SCHEDULE number is entered, the set output schedules
are displayed.
(3) Press the "PEAK POWER" setting button.
Enter the laser output peak value by using the numeric keypad and then press
the ENT key.
In this example, set 5.00 kW.
Summary of Contents for ML-2350A-CE
Page 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 118: ......
Page 128: ......
Page 150: ......
Page 174: ......
Page 179: ...Maintenance Part...
Page 180: ......
Page 209: ...Appendixes...
Page 210: ......