Timing Chart
221
ML-2350A/2351A
Repeated operation (25 pps or more) (EXTERNAL CONTROL)
The following diagram shows the lapse of time in the case where laser is output
according to the number of repeated outputs of 25 pps or more.
*1 60s max.
Charging time. When a high voltage is turned ON and charging is
completed, the READY status is provided.
*2 150ms or more
Shutter operation time
*3 5ms min.
Monitor error output time. Minimum error output time for 200 pps.
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
*2
High Voltage ON Output
Ready Output
Schedule 1 to 16 Input *
Beam Select
1 to 6 Input *
Laser Start Input *
Laser Stop Input *
(Laser light)
END Output
Monitor Normal Output
Monitor Trouble Output
(*: Operation on the user side)
(After a laser output, the charging status may lower.)
60s max.
150ms
or more
5ms min. (200pps) *3
*1
The time set on the MEMORY SWITCH screen or more