198
ML-2350A/2351A
3. Maintenance of Laser Oscillator Section
3
Making an Operation Check
(1) Put the lamp-replacing cover. It is not necessary to tighten the screws.
(2) Turn ON the MAIN POWER switch.
(3) Turn ON the CONTROL keyswitch to run the cooler.
⇒
When the CONTROL keyswitch is turned ON, a bit of water may ooze out from
the clearance between the laser chamber and the top lid. This is due to pushed
waterdrops around the packing groove and is not abnormal. Wipe them out with
a clean cloth.
(4) Turn OFF the CONTROL keyswitch and remove the lamp-replacing cover.
(5) Check for water leakage.
⇒
If water leakage occurs, turn OFF the MAIN POWER switch immediately. In 5
minutes or more, wipe out leaked water and remove the cause for water leakage.
Then, operate the cooler again to make sure that no water leakage occurs.
(6) Install the lamp-replacing cover.