80
ML-2350A/2351A
1. Setting Welding Schedules
2
Setting ON/OFF for the Output Conditions for Seam Welding
(1) Press the "SEAM" setting button and set the seam welding output condition to
ON/OFF.
At ON, the fade function for seam welding set on the SEAM screen is enabled.
When this function is not used, set OFF.
⇒
When the "SEAM" button for screen switching is pressed, the SEAM screen
appears and the output conditions for seam welding can be set. For the setting
method, refer to "Setting the Output Conditions for Seam Welding" on page 83.
3
Checking Output Schedules
(1) Check the waveform displayed on the screen.
The set laser output time and laser output value are graphically displayed and
the output laser light can be checked as a waveform.
⇒
At the leading edge of waveform, an overshoot (higher form than the set value)
may occur. In this case, extend "
SLOPE" by 0.1 to 1.0 ms.
(2) Check the output energy displayed in "REFERENCE VALUE."
⇒
In "REFERENCE VALUE", the forecast value of laser output energy based on the
set output schedules is displayed. This value is a little different from the actually
measured value (measured value displayed on the MONITOR screen) provided
at laser welding. However, use it as reference.
↑
SLOPE 0.5ms
FLASH1 1.0ms
FLASH2 1.5ms
FLASH3 3.0ms
↓
SLOPE 1.0ms
Pulse width 5.5ms
5ms
100%
Summary of Contents for ML-2350A-CE
Page 1: ...AA06OM1173714 18 OPERATION MANUAL YAG LASER WELDER ML CE 2350A 2351A Original instructions...
Page 19: ...Introduction Part...
Page 20: ......
Page 37: ...Installation and Preparation Part...
Page 38: ......
Page 46: ......
Page 57: ...Operating Part...
Page 58: ......
Page 118: ......
Page 128: ......
Page 150: ......
Page 174: ......
Page 179: ...Maintenance Part...
Page 180: ......
Page 209: ...Appendixes...
Page 210: ......