M
ANAGEMENT
I
NTERFACE
The following table describes the items in the previous menu.
Table 3-13.
Management > Power over Ethernet > Global Configuration and
Status
Parameter
Description
Admin Mode
Click the drop-down menu to enable or disable the admin mode. The default is
Enable.
Power Budget (1/10
Enter a value [between 342 to 342 x (maximum of copper PoE port) to specify PSE
Watts)
maximal supplying power. The unit is 0.1 watt.
Power Consumption
Displays the power consumption of PSE’s total real-time power consumption. It's
(Watts)
the summary of all PSE ports.
Power Usage Alarm
Enter a power usage alarm threshold (between 1 to 99). The default is 99.
Threshold (%)
Cumulative Power
Displays the cumulative PSE total power consumption. It's the summary of all PSE
Consumption (Kilo-
ports. The unit is KWH (kilowatt hour).
Watts/Hour)
Current Measured
Displays the total real-time output current of PSE. It's the summary of all PSE
(mA)
ports. The unit is mA.
Voltage Guard
Enter a value (between 500 to 620) to specify the PSE over-load guard voltage.
Threshold (1/10V)
The unit is 0.1 voltage. The default is 620.
Power Supply Volt-
Displays the input voltage of power supply units. The unit is voltage.
age (V)
Temperature Guard
Enter a value (between 60 to 155) to specifies PSE over-heat guard temperature.
Threshold (Celsius)
The unit is celsius. The default is 150.
PoE Temperature
Displays the PSE operation temperature. The unit is celsius.
(Celsius)
Fault Indication
Displays the PSE global fault indication.
None - Specifies PSE detects no error condition.
Power-Absent - Specifies absence of PSE input power.
Abnormal-Voltage - Specifies the measured PSE input voltage exceeds guard
threshold.
Over-Heat - Specifies the measured PSE temperature exceeds guard thresh-
old.
Other-Fault - Specifies PSE detects fault condition which not listed in selection.
Submit
Click
Submit
to update the screen. To save the values across a power cycle per-
form a system save.
Refresh
Click
Refresh
to update the screen.
Interface Configuration and Status
Users can enable or disable the Admin Mode through the drop down menu, and configure the
Power Budget, Power Priority, and Power Pairs. To access this page, click
Management
>
Power over Ethernet
>
Interface Configuration and Status
.
53