34
Signal Connections
3.10 Isolated Digital Output DOx
The connection of isolated-digital output is shown in the following
diagram. When the isolated digital output goes to high, the sink
current will be from external DOUT supplied voltage. Each transis-
tor on TD62083 is OFF when reset.
Spec. of TD62083
X
Output sustaning voltage: 50V
X
Output Current: 123 mA/ch (Duty=50%), 500 mA/ch (MAX)
X
Clamp Diode Reverse Voltage: 50V
X
Clamp Diode Forward Current: 500mA
X
Power Dissipation: 1.47W (maximum)