Name
Type
Values (Range)
Unit
Description
DIR_A
Enum
0=unknown
1=forward
2=backward
3=both
Direction phase A
DIR_B
Enum
0=unknown
1=forward
2=backward
3=both
Direction phase B
DIR_C
Enum
0=unknown
1=forward
2=backward
3=both
Direction phase C
ANGLE_A
FLOAT32
-180.00...180.00
deg
Calculated angle difference,
Phase A
ANGLE_B
FLOAT32
-180.00...180.00
deg
Calculated angle difference,
Phase B
ANGLE_C
FLOAT32
-180.00...180.00
deg
Calculated angle difference,
Phase C
67/50P
Enum
1=Enabled
2=blocked
3=test
4=test/blocked
5=Disabled
Status
4.1.3.11
Technical data
Table 112:
67/51P and 67/50P Technical data
Characteristic
Value
Operation accuracy
Depending on the frequency of the current/voltage
measured: f
n
±2 Hz
67/51P
Current:
±1.5% of the set value or ±0.002 × I
n
Voltage:
±1.5% of the set value or ±0.002 × V
n
Phase angle: ±2°
67/50P-1 and 67/50P-2
Current:
±1.5% of the set value or ±0.002 × I
n
(at currents in the range of 0.1…10 × I
n
)
±5.0% of the set value
(at currents in the range of 10…40 × I
n
)
Voltage:
±1.5% of the set value or ±0.002 × V
n
Phase angle: ±2°
Pickup time
1)2)
Minimum
Typical
Maximum
I
Fault
= 2.0 × set
Pickup
value
38 ms
43 ms
46 ms
Reset time
<40 ms
Table continues on next page
Section 4
1MRS240050-IB C
Protection functions
160
REF615R
Technical Manual
Summary of Contents for RELION REF615R
Page 1: ... RELION PROTECTION AND CONTROL REF615R Technical Manual ...
Page 2: ......
Page 27: ...Section 18 Glossary 653 Table of contents REF615R 21 Technical Manual ...
Page 28: ...22 ...
Page 36: ...30 ...
Page 46: ...40 ...
Page 115: ...3 15 4 Settings 1MRS240050 IB C Section 3 Basic functions REF615R 109 Technical Manual ...
Page 118: ...112 ...
Page 318: ...312 ...
Page 388: ...382 ...
Page 456: ...450 ...
Page 520: ...514 ...
Page 652: ...646 ...
Page 656: ...650 ...
Page 658: ...652 ...
Page 663: ...657 ...