![ABB AC500-S Safety User Manual Download Page 439](http://html.mh-extra.com/html/abb/ac500-s/ac500-s_safety-user-manual_2916439.webp)
Name
Data type
Description
S3_S_Switch2
BOOL
Switch S3 related to push button 2 of two hand control
K1_S_EDM1
BOOL
Feedback from external device K1
K2_S_EDM2
BOOL
Feedback from external device K2
S0_Reset
BOOL
Reset by user via Switch S0 (derived from the functional applica-
tion)
Process
BOOL
Enabling motion by the process (derived from functional application)
Table 98: Outputs
Name
Data type
Description
S_EDM_Out_EDM_
K1_K2
BOOL
Drives actuator via K1 and K2
All Errors
BOOL
Represents all error BOOLs of the used FB (connected to the func-
tional application)
All DiagCodes
WORD
Represents all diagnostic codes of the used FB (connected to the
functional application)
Safety application examples
Example 3: Two-hand control > Declaration of used variables
30.03.2017