![ABB AC500-S Safety User Manual Download Page 343](http://html.mh-extra.com/html/abb/ac500-s/ac500-s_safety-user-manual_2916343.webp)
DiagCode
State Name
State Description and Output Setting
8003
Wait for Reset Safety demand or errors have been detected and are now cleared. Oper-
ator acknowledgment by Reset required.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
8005
Safe
Safety function activated.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
8011
Muting For-
ward Start
Muting forward, sequence is in starting phase and no safety demand.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = FALSE
Error = FALSE
8012
Muting For-
ward Active
Muting forward, sequence is active.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = TRUE
Error = FALSE
8112
Muting Back-
ward Active
Muting backward, sequence is active.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = TRUE
Error = FALSE
8122
Muting Back-
ward Start
Muting backward, sequence is in starting phase and no safety demand.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = FALSE
Error = FALSE
Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
30.03.2017
AC500-S