![ABB AC500-S Safety User Manual Download Page 307](http://html.mh-extra.com/html/abb/ac500-s/ac500-s_safety-user-manual_2916307.webp)
Table 54: FB Name: SF_TwoHandControlTypeII
Name
Data Type
Initial Value
Description, Parameter Values
VAR_INPUT
Activate
BOOL
FALSE
Table 31 “General Input Parameters”
S_Button1
BOOL
FALSE
Variable.
Input of button 1 (for category 3 or 4: two antiva-
lent contacts)
FALSE: Button 1 released.
TRUE: Button 1 actuated.
S_Button2
BOOL
FALSE
Variable.
Input of button 2 (for category 3 or 4: two antiva-
lent contacts)
FALSE: Button 2 released.
TRUE: Button 2 actuated.
VAR_OUTPUT
Ready
BOOL
FALSE
Table 32 “General Output Parameters”
S_TwoHandOut
BOOL
FALSE
Safety related output signal.
FALSE: No correct two hand operation.
TRUE: S_Button1 and S_Button2 inputs are
TRUE and no error occurred. Correct two hand
operation.
Error
BOOL
FALSE
Table 32 “General Output Parameters”
DiagCode
WORD
16#0000
Table 32 “General Output Parameters”
Notes: No Reset input or Error output is required, because no test can be performed on both switches.
Configuration and programming
AC500-S Libraries > SafetyBlocks_PLCopen_AC500_v22.lib
30.03.2017
AC500-S
307