![ABB AC500-S Safety User Manual Download Page 427](http://html.mh-extra.com/html/abb/ac500-s/ac500-s_safety-user-manual_2916427.webp)
7.2.2 Graphical overview of safety application interface
Safety Application
S1_S_EStopIn_1
Functional Application
Standard
Outputs
S1
DiagCodes
Errors
S_Stopped
S0
S1_S_EStopIn_2
S3
Emergency
Stop
S0_Reset
EStop
Reset
Safety
Input
Standard
Input
S3_Drive_Reset
Drive Error
Ackonwledge
S0_Reset
All DiagCodes
& All Errors
Visualization
Safety Drive
Axis 1
Safety
Input
SF_SafeStop1_1
Safety
Inputs
S2
S2_S_ESPE_In
Light
Curtain
Standard
Inputs
Fig. 134: Graphical overview of the example with emergency stop
The symbol represents a direct opening action
(
Ä
IEC 60947-5-1
).
7.2.3 Declaration of used variables
Table 90: Inputs
Name
Data type
Description
S1_S_EstopIn_1
BOOL
Emergency Stop Channel 1
S1_S_EstopIn_2
BOOL
Emergency Stop Channel 2
S2_ESPE_In
BOOL
Light curtain signal
S0_Reset
BOOL
Reset Emergency Stop and ESPE
S3_Drive_Reset
BOOL
Reset Drive Error
Table 91: Outputs
Name
Data type
Description
S_Stopped
BOOL
Indication of Safe Stop of drive
All Errors
BOOL
Errors of SF_Function Blocks
All Diagcodes
BOOL
Diag codes of SF_Function Blocks