6.Measuring Input Signals - 6.3.Starting and Ending Recording
1WMPD4004444
63
(5) Start time + Start trigger
Start trigger occurs
Recording ends
Press START key
Recording time
Start time
During record
Printer recording
SSD recording
Memory recording
Trigger occurred Trigger occurred Trigger occurred
When the START key on the operation panel is pressed, the product enters the measurement standby
state after the time set in Start time . Recording to the various devices starts when the channel trigger
specified in Start trigger is occurred, and continues until the time set in Recording time in the
recording setup elapses or the STOP key on the operation panel is pressed.
(6) Start t Interval (N times)
Start trigger occurs
Interval time
START trigger occurs
Press START key
1 time
N times End recording
Recording time
Recording time
During record
During record
Printer recording
SSD recording
Memory recording
Trigger occurred Trigger occurred Trigger occurred
When the START key on the operation panel is pressed, the product enters the measurement
standby state and recording starts when the channel trigger specified in Start trigger is occurred.
Measurement continues until the time set in Recording time in the recording setup elapses, and then
the next recording starts when the time in Interval time elapses after recording starts, and the
product waits for the next start trigger.
Summary of Contents for RA3100 Omniace
Page 1: ...RA3100 Omniace Instruction Manual 1WMPD4004444...
Page 173: ...13 Optional Parts 13 2 List of Probes Clamp Meters 1WMPD4004444 173 MEMO...
Page 174: ...13 Optional Parts 13 4 List of Spare Parts 174 1WMPD4004444 MEMO...
Page 175: ...Omniace RA3100 Instruction Manual 1WMPD4004444 1st Edition...