6.Measuring Input Signals - 6.3.Starting and Ending Recording
62
1WMPD4004444
(3) Start trigger
Start trigger occurs
Recording ends
Press START key
Recording time
During record
Printer recording
SSD recording
Memory recording
Trigger occurred Trigger occurred Trigger occurred
When the START key on the operation panel is pressed, the product enters the
measurement standby state. Recording to the various devices starts when the channel trigger
specified in Start trigger is occurred and continues until the time set in Recording time in
the recording setup elapses or the STOP key on the operation panel is pressed.
(4) Interval (N times)
Interval time
Press START key
1 time
N times End recording
Recording time
Recording time
During record
During record
Printer recording
SSD recording
Memory recording
Trigger occurred Trigger occurred Trigger occurred
When the START key on the operation panel is pressed, recording to the various devices starts and
continues until the time set in Recording time in the recording setup elapses, and then the next
recording starts when the time in Interval time elapses after measurement starts. Measurement ends
when recording has been performed the number of times specified in Number of Recording times for
the interval.