Order no.
031-1LB90
Radical error limit current ranges with SFU
-
Destruction limit current inputs (voltage)
-
Destruction limit current inputs (electrical current)
-
Resistance inputs
-
Resistance ranges
-
Operational limit of resistor ranges
-
Operational limit of resistor ranges with SFU
-
Basic error limit
-
Basic error limit with SFU
-
Destruction limit resistance inputs
-
Resistance thermometer inputs
-
Resistance thermometer ranges
-
Operational limit of resistance thermometer ranges
-
Operational limit of resistance thermometer ranges with
SFU
-
Basic error limit thermoresistor ranges
-
Basic error limit thermoresistor ranges with SFU
-
Destruction limit resistance thermometer inputs
-
Thermocouple inputs
ü
Thermocouple ranges
type B
type C
type E
type J
type K
type L
type N
type R
type S
type T
Operational limit of thermocouple ranges
Type E, L, T, J, K, N: ±2.5K / Type B, C, R, S: ±8.0K
Operational limit of thermocouple ranges with SFU
Type E, L, T, J, K, N: ±1.5K / Type B, C, R, S: ±4.0K
Basic error limit thermoelement ranges
Type E, L, T, J, K, N: ±2.0K / Type B, C, R, S: ±7.0K
Basic error limit thermoelement ranges with SFU
Type E, L, T, J, K, N: ±1.0K / Type B, C, R, S: ±3.0K
Destruction limit thermocouple inputs
max. 20V
Programmable temperature compensation
ü
External temperature compensation
ü
Internal temperature compensation
ü
VIPA System SLIO
Analog Input
031-1LB90 - AI 2x16Bit TC > Technical data
HB300 | SM-AIO | | en | 17-05